2U and 3U Storage Chassis CPU Cooler Height and Rack Depth

Compare CPU cooler height limits, chassis depths, and rail mounting ranges for four 2U and 3U storage chassis. Check drive-cage clearance and rack fit.

Illustrated title card for the guide: 2U and 3U Storage Chassis CPU Cooler Height and Rack Depth

For a 2U or 3U storage chassis, check the cooler limit at the CPU socket, the space for the chassis and cables, and the slide kit’s mounting range. The 2U-2404S allows just 32 mm under its drive cage, while the 3U-3416 lists 113 mm of cooler clearance and a 688 mm case depth. 2U-2404S specs, 3U-3416 specs, TOTEN rack depth guide.

Cooler height, chassis depth, and rail fitment

Inter-Tech chassisHot-swap baysMaximum CPU cooler heightPublished case depthListed slide rails
2U-2404S432 mm if the CPU is under the drive cage, otherwise 65 mm438 mm455 mm or 650 mm 2U slides
2U-2408865 mm688 mm455 mm or 650 mm 2U slides
3U-35088100 mm528 mm18-, 20-, or 26-inch rails with 10 mm mounting width
3U-341616113 mm688 mm455 mm or 650 mm 2U slides

Use the kit’s published mounting depth to check the distance between your rack’s front and rear posts. The 3U-3416 lists the same 2U-named slides as the two 2U cases above. 3U-3416 accessory list, TOTEN rack depth guide.

Inter-Tech rail kitPart numberRack mounting depth
455 mm 2U slides88887221500 to 800 mm
650 mm 2U slides88887211690 to 1,000 mm
18-inch rail, 10 mm mounting width88887195490 to 600 mm
20-inch rail, 10 mm mounting width88887204440 to 670 mm
26-inch rail, 10 mm mounting width88887129580 to 850 mm

For the 18-, 20-, and 26-inch kits, the mounting depth depends on how the rails are installed. Each kit in the table has a published maximum load of 30 kg. 455 mm specs, 650 mm specs, 18-inch specs, 20-inch specs, 26-inch specs.

Check cooler height at the socket

In the 2U-2404S, check whether the CPU sits under the drive cage. Use the 32 mm limit under the cage and the 65 mm limit otherwise. Compare the cooler’s published height with the limit for that CPU position. Inter-Tech 2U-2404S clearance footnote.

Check cabinet depth and rack-post spacing

The cabinet’s outside depth and the distance between its front and rear posts are different measurements. Check the cabinet drawing for both. TOTEN rack depth guide.

  • Cabinet clearance. Use the chassis and cabinet drawings to check the space available with the doors closed. Account for the chassis, mounting hardware, rear plugs and cable bends. Use the clearance requirements for your equipment and cables. TOTEN rack depth guide.
  • Rail spacing and load. Check the front-to-rear mounting distance at the planned post positions against the exact rail kit’s range. Check the kit’s bracket arrangement and compare its load limit with the weight of the fully equipped chassis. TOTEN rack depth guide, 455 mm slide specifications and documentation.

Worked rail check. With 600 mm between the posts, the 455 mm 2U slides pass the depth check because their range is 500 to 800 mm. The 650 mm 2U slides require at least 690 mm. On the 688 mm-deep 3U-3416, cabinet and cable clearance still need a separate check. 455 mm slide specs, 650 mm slide specs, 3U-3416 specs, TOTEN rack depth guide.

Evidence and limits. The Inter-Tech product specifications for the listed models and TOTEN cabinet guidance were checked on November 27, 2026. The fitment checks were not performed on hardware.

Sources

  1. Inter-Tech 2U-2404S
  2. Inter-Tech 2U-2408
  3. Inter-Tech 3U-3508
  4. Inter-Tech 3U-3416
  5. Inter-Tech 2U Telescopic Slides 455 mm
  6. Inter-Tech 2U Telescopic Slides 650 mm
  7. Inter-Tech 18-inch Telescopic Rails
  8. Inter-Tech 20-inch Telescopic Rails
  9. Inter-Tech 26-inch Telescopic Rails
  10. TOTEN server rack depth guide

Related bins